Enter your requirements and local pros will bid on your service, providing a quote to complete your request. Normally, water travels in one direction, from treatment plants, through water mains, then to each customers service connection. the system pressure has been increased by A public water systems Cross-Connection Control Program is inspected during routine investigations made by our regional staff. This is not a complete list of all certified testers in this Position Overview. All vaults and enclosures for backflow assemblies must be kept free of any debris and/or objects that interfere with these installation requirements and those applicable to OAR 333-061-0071. Join to apply for the ENVIRONMENTAL INVESTIGATOR I/RC role at City of Houston. Are you a Local Pro? Upon completion of a premises-isolation backflow assembly installation, Portland Water Bureau Water Quality Inspection must be notified. between one and 5-feet AFF, the assembly must be installed at water service entrance elevation. Back-siphonage backflow caused by a negative pressure (i.e., a vacuum or partial vacuum) in the drinking or public water system. . Fax the completed Plumbing Permit Application (CE-1020) to the Permits Office at 832-395-9621. Vault lids with hinged frame and covers (Oldcastle Infrastructure or equivalent): where applicable use Center-Offset frame and cover lids (Oldcastle Infrastructure or equivalent). The relief-valve must be located 12 above the top of the vault drain opening. A Double Check Detector Assembly (DCDA) is typically the type of backflow assembly installed on fire sprinkler water services. In addition to City Code Title 21 and Title 28, OAR 333-061-0070, Section 14, will apply to all existing premises-isolation backflow assembly installations. In the case of parallel Reduced pressure assemblies the lower of the two will need to extend beyond the 4 minimum clearance behind to accommodate a drain assembly for relief valve orifice of the assembly above. The air-gap must never be less than 1. Check or Money Order ONLY. TCEQ regulations require that any alternate forms which vary from the official forms receive TCEQ approval prior to being placed in use. Your water systems role begins with good system maintenance and sound operations. Water and pesticides flowed from the pesticide tank back through the hose and into the water lines of the residence. A minimum of a Double Check Valve Assembly (DCVA) for premises-isolation must be installed on water services: If the water meter is 2-inches or larger. Some public water systems have licensed staff who perform the CSIs and then bill the customer for the inspection. A premises-isolation reduced pressure type backflow assembly is required to be installed on all water service connections as listed but not limited to: premises having private wells, water features (swimming pools), geothermal heating & cooling systems, hydronic heating systems, cooling towers, that have access to rivers, lakes, ponds and/or other water sources that can be connected to; are equipped with storage tanks, rainwater-harvesting (excluding those that simply capture rainwater in containers of less than 50 gallons and gravity-feed to landscape), storm-water or groundwater recovery and reuse systems and/or that use, or reuse treated wastewater (grey and/or black-water) on site. Schedule single and recurring services via the SwiftQuote Web App through any device. All rights reserved. FAX: 206-824-0806 Please include Cross-Connection/Backflow Prevention in the subject line of your e-mail. Phone: 206-824-0375 Backflow prevention assembly requirements are determined by plumbing inspections performed at initial or remodel construction projects during the Building Permit Process. Finding a reliable backflow tester doesnt have to be a risky or time-consuming process. Assemblies over 2 inches in size (includes 2-inch DCDA/RPDA) must be supported by rigidly mounted metal supports (Standon Pipe Supports or equivalent) underneath the shut-off valves at both ends of the assembly. Additionally, all piping for fire sprinkler system backflow assembly installations must be compliant with the local Fire code. (Minimum Permit Fee is $91.05). Have a High School Diploma or Equivalent Certificate, Pass an examination *Written exam must be taken at a TCEQ regional office or proctored computer-based testing facility as of May 2, 2016, Work at least two years in an approved area. HVK%')dVe%X[oLWR=I Dtrtq3,Vg(&_[N?YG5P[IYH^h\z=d+k,IU%TgrtM%gNYc8-@OiGW.ili\B,|g6 ,~=z. 3. For the safety of its public water supply, the City diligently ensures that homes and businesses are in compliance with cross-connection/backflow requirements. See something we could improve onthis page? RPBA installations must meet all applicable Oregon Administrative Rules, 333-061-0070, Title 21, and Title 28, respectively. A moisture-proof light fixture will be required if adequate lighting is not available. Effective September 1, 2017, pursuant to TCEQ Reg-521 "Criminal History Guidelines", those with a felony criminal history should contact TCEQ Licensing Division prior to registering for a training course. 1. Click Here for the requirements to register with the City of Houston as a backflow prevention assembly tester. If for the installation of a main shutoff valve, emergency shutoff valve, or to accommodate drainage for a RPBA relief-valve, the assembly may be placed at an elevation greater than the minimum. Water service must not be activated and is subject to termination without notice until all backflow assembly installation related work has been completed. Search pros in your area and select based on reviews, price, and any other requirements. Copyright 2021 Hardin & Associates Consulting. All backflow assemblies installed below grade must be provided with test cock plugs. Only approved Double Check Valve and Reduced Pressure type backflow assemblies, may be used for premises-isolation backflow protection. At least 6-feet of vertical headroom is required for all vault, chamber, enclosure, and basement installations. Typically, backflow prevention assemblies are required for plumbing system connections that contain industrial fluids or chemicals, irrigation systems, fertilizers, or auxiliary water sources (including reclaimed water). Apply in person at 1002 Washington Avenue, Houston, TX 77002 or at one of the Satellite Offices. {a$7@!!3ItPdQOx&V>K2[v:O2&Wi,a/%(&*KR&%lA2JE1"a&3"A DD1NuVU-EVV>}*fx+K!^UP|+Gpr,'H_Z9[9.rrU'A/{R/@8WW?.^Wy1iZ_'~A8UIyO32awJ{'3l}4{?jZF=P|l>}7WQu%XD"R'7s/[. Backflow is the unintended flow of water from any domestic, industrial or institutional piping system into a drinking water supply system. forcing it into a clogged gutter, downspout, or sewer pipe to flush out the clog, connecting it directly to a hose-end sprayer to apply pesticide or fertilizer to your yard, connecting it to a soap-and-brush attachment to wash your car, boat, or siding, letting the end of the hose lie in a puddle or pool of water on the ground. Maintenance requirements include regular testing based on the type of device being used. Note: A Reduced Pressure Detector Assembly (RPDA) is required to be installed where; storage tanks are provided, if the structure is considered a high-rise (requirement stated herein) if supplying marinas, moorages, premises having docks and piers, when rainwater-harvesting, storm-water and/or groundwater recovery and reuse systems are installed and/or that use, or reuse treated wastewater (grey and/or black-water). Monday - Friday 8:00 a.m - 5:00 p.m. United States, Backflow Prevention Assembly Tester Information, Backflow Prevention Assembly Tester Registration Instructions, List of Backflow Prevention Assembly Testers, Approved Backflow Prevention Assemblies List. Items can be submitted to our office . Kent, WA 98032 Password (8+ characters) You may also apply directly on company website . A premises-isolation RPBA must be installed on all water service connections that pose a risk to health. The Cross-Connection Control Subcommittee advises us in this effort. Separation must be at least twice the diameter of the water supply outlet and never less than one inch. The Installer/Contractor will request a (Code418) inspection via phone by calling the Voice Permits (IVR) at 817-392-6370 or through the City of Fort Worth Development Services Department at 817-392-2222. Make sure that the end of your garden hose is never submerged in or connected to a nonpotable substance. For this reason, all certified backflow prevention assembly testers are responsible for the accuracy of their field-testing and of their Test and Maintenance Reports. The airgap must be at least twice the inside diameter of the relief-valve, measured vertically above the top of any drain or receiving vessel. The only thing you pay for is your service booked through the platform. For your convenience we provide 7. CE hours are given for successful completion of TCEQ approved training courses. City of Houston - Backflow Assembly & Test Report Form. For single & multiple assembly installations, refer to item #2 above to ensure proper ladder placement. This applies to all below grade new service and retrofit of existing service installations. Foundations, footings, slabs and/or walls must be sleeved or core-drilled to accommodate code compliant riser/supply pipe entrance locations. Backflow Prevention Assembly Tester Registration Instructions List of Backflow Prevention Assembly Testers Water Protection Hazard List Approved Backflow Prevention Assemblies List Test and Maintenance Requirements Contact Info 512-972-1060 ext. Full opening double doors (Oldcastle Infrastructure 332P-2 or EJ USA Inc. #8127-Double or equivalent) can be used to obtain the 6-foot requirement but must encompass the entire lay-length of the assembly and must not encroach on required ladder clearances. Opportunities posted to governmentjobs.com, Legal and installation requirements for backflow protection, City of Portland general information hotline, Backflow prevention and cross-connection control, Oregon Health Authority (OHA) Cross-Connection Control Requirements, Backflow assembly installation requirements, Submitting backflow assembly test reports, Portland Water Bureau manuals and design standards, install a backflow prevention assembly if there's an existing or potential cross-connection on your premises, immediately have your assembly cleaned, repaired or replaced if not working properly. Tablet PCs running Windows 10 must run Windows 10 Home, Pro, or Enterprise. Many public water systems also operate rigorous cross-connection control (CCC) programs of their own. You can find one from our, If you install your own system, have a licensed BPA tester confirm that the BPA is installed and operating properly. The touchpad must be accessible from the right-of-way. {R/ONU1#>he I5ce;, The parallel elbows shall be no more than 12 off the centerline of the TEE. The following individuals are authorized to perform CSIs: OurOccupational Licensing Sectionlicenses Customer Service Inspectors and maintains a database of licensed Customer Service Inspectors. endstream endobj startxref The ladder must be mounted vertically in the entryway of the vault or chamber and be securely anchored at top and bottom. This can be caused by backsiphonage or backpressure. Tablet PCs only support the desktop client. A list of Tucson Water-approved Certified Testers is available. Testing and repairing backflow prevention assemblies on fire suppression systems and lines. Services entering at an elevation greater than 5-feet above-finished-floor (AFF) will require a permanent platform be installed. Hours: M-F 7:00-4:00, Copyright 2016 Highline Water District |. However, certain pressure variations in the public water supply can cause water to flow in the opposite direction. This usually occurs in unvented heating systems, where SwiftQuote integrates with your municipality and uploads compliance records to the city on your behalf. An approved rigidly mounted ladder, with an extension which extends 3 above the vault lid (Oldcastle Infrastructure Pull-Up Extension, Bilco LU-1 or equivalent) is required if the vault or chamber is 4 or greater in depth. Backflow is the reversal in the direction of the normal flow of water in a piping system. Permit must be obtained by a master plumber or irrigatorregistered with the City of Houston. Backflow Prevention Information | City of Houston - Houston Public Works Backflow Prevention Information All certified backflow prevention assembly testers play an important role in protecting the City of Houston water customers. The simplest method to prevent backflow is to have your backflow assembly tested on an annual basis. For 1 and smaller assemblies, Carson Industries box #1419-18 is recommended or equivalent. No pressure testing is to be performed between a premises-isolation assembly and a Water Bureau valve in the right-of-way. 8. 2023. 1750 12 th Street Sarasota, Florida 34236. All Rights Reserved. Is the assembly installed in accordance with manufacturer recommendations and/or City's Uniform Plumbing Code? 10. You can then select your preferred provider and schedule the service. Back siphonage is the result of supply pressure being lowered A RPBA is required where the water is treated in any way. An alternate assembly location may only be considered for retrofit applications and excludes new construction. state. A webcam or HD webcam - built-in, USB plug-in, or: An HD cam or HD camcorder with a video-capture card, Virtual camera software for use with broadcasting software like OBS or IP cameras. General Info (843) 727-7148. K/7tLb"bxOEuY# O>X}xww-[wZ|=m~8Y{&TXcSv>:.8gXq.ih/}^Mz]z>,NwUUC1->`}>TM;]~a^mvoOzm0P9CLN=MMdD,F?oil1jB).1xU]0SM^D7iLbas,=?W_OFZTum LAq0 d$jpwzcZ hdl%P+]/PGjS)EKafdm50jL:9~I^X#R. In no circumstance may the lower assembly be less than 12 AFF (measured to the lowest point on the assembly) and the higher assembly may not be installed above 5 AFF (measured to the top of the assembly body) unless an OSHA approved permanently mounted platform is installedthat meets the standards as outlined herein. All applicable RPBA installation criteria will apply. List of Testers Email Us Questions? For horizontal installations, and for assemblies which are not approved for vertical up installation, the riser must be equipped with a single 90-degree elbow and the assembly is to be no more than the pipe diameter in inches beyond the centerline (or outlet side of the) elbow to accommodate horizontal installations, excepting only the addition of a wye-strainer, flood control shut off valve or other, necessary appurtenance. 205 0 obj <>/Filter/FlateDecode/ID[]/Index[175 60]/Info 174 0 R/Length 134/Prev 362807/Root 176 0 R/Size 235/Type/XRef/W[1 3 1]>>stream Vertical, physical separation between the end of a water supply outlet and the flood-level rim of a receiving vessel. NEW: HAC is now offering free on site gauge certification to each registered student. Some appliances have built-in backflow prevention for this reason, but many do not. The proposed installation of a RPBA in an area that may be subject to flooding must be reviewed and approved by Portland Water Bureau Water Quality Inspection prior to installation. FEMA has listed several requirements below as a quick reference, but it is encouraged to refer to the funding opportunity for a full list of all requirements. This list is provided merely for the convenience of the For more information on protecting your water, contact the City's Backflow Prevention Inspector at (585) 428-6070 . Call 520-791-2650 if you would like more information. May be mounted on the vault door. Some Public Water systems may have more stringent requirements than the TCEQ. 10. Assemblies larger than 2 (Includes 2 fire service DCDAs (see fire sprinkler information), only pre-cast vaults (Oldcastle Infrastructure or equivalent) that accommodate the installation criteria will be accepted. Request these services online or call 503-823-4000, Relay Service:711. 2. By continuing to use this website, you consent to the use of cookies in accordance with our Cookie Policy. 11. When a Double Check Valve Assembly (DCVA) or a Double Check Detector Assembly (DCDA) is installed in a vault the following must be provided: 1. 797 0 obj <>stream CT's Firm Name: Tester Name: Firm . If the first upstream manhole is at a higher elevation due to the natural opography of the t area, an alternate method may be selected by the Utility's Development Services Department for the purpose of determining the feasibility of gravity connection. Sump pump discharge piping must meet vault drainage requirements as stated herein. . All backflow prevention assembly tester licenses require 24 hours of Continuing Education (CE) to be eligible for renewal. Give website feedback. Your water provider may have adopted additional codes or regulations which require. These devices are subject to annual inspection, maintenance, testing and reporting requirements to ensure each device continues to protect against cross connections. testers contained on this list. This solution is free, but not highly reliable. 12. 5. testers. An inspection fee must be paid to the Water Bureau prior to replacement of an existing assembly or newly installed assembly on a dedicated fire service. Approved Areas per TCEQ (click link for more details): Operating or maintaining a Public Drinking Water System, Installing or repairing residential, commercial, or industrial drinking water treatment equipment, Installing or repairing lawn irrigation systems, Performing activities requiring a Master or Journeyman Plumbing license, Testing and repairing backflow prevention assemblies on fire suppression systems and lines. For example, these and other businesses would be required to install high-grade backflow prevention assemblies and have them tested by a certified tester annually: Another aspect of an effective CCC program is the customer service inspection (CSI). Additional gauges can be certified for $70 per gauge. Under normal operation water flows from the City of Houston waterlines to the water customers. All Double Check Detector Assemblies (DCDAs) and Reduced Pressure Detector Assemblies (RPDAs) required to be installed by the Portland Water Bureau must be equipped with a Water Bureau approved bypass meter and compatible touchpad. Platforms must be engineered to comply with all applicable Oregon OSHA requirements and be detailed on all drawings submitted for review and permitting through City of Portland Bureau of Development Services (BDS). The supply side of premises-isolation assemblies must be plumbed with potable water piping and fittings meeting current NSF/ANSI standards for lead content. . Touchpads or transmitters must be rigidly mounted and be serviceable. It can be caused by a loss of pressure in the drinking water supply main or by the flow from a pressurised system through an unprotected cross connection. Registers must read in cubic feet. 13. 18. State rules and City Codes require you to: Backflow Assembly Installation Requirements. Testing and Maintenance Reports (TMRs) Each BPAT must submit a complete and legible Test and Maintenance Report (TMR) to the Austin Water Utility for each BPA tested. The requirements on this page and Title 21City Water Code require property owners to install backflow assemblies to protect the public drinking water supply. hb``a``d`c`Lcb@ !FV&m3@(Z R pGAsD / 6/`9ARTkX[Turd_0 ' This will facilitate their registration to perform "authorized functions" under the proposed Backflow Prevention By-law and make available remedies under the Licensing Code should they fail to meet that By-law's requirements. If the fire sprinkler service is fully metered (a meter approved by the Water Bureau for fire flow application and billing purposes) a Double Check Valve Assembly (DCVA) or Reduced Pressure Backflow Assembly (RPBA) may be installed depending on sprinkler system type. State and/or City required premises-isolation backflow protection is a condition of water service or continued service where an existing service requires premises-isolation protection. Title 21.24.040 requires access be granted to all premises for inspection of water piping, as described therein. Planning, outreach and education, strategic, and technology projects. If the Water Bureau determines the backflow potential warrants and the use does not pose a risk to health. If it is determined by the Water Quality Inspector that arbitrary runs of exposed piping have been installed prior to an assembly, the assembly may either be required to be relocated or the piping be sleeved. The tester's role is to verify the proper operation of the assemblies. Premises-isolation backflow assemblies must be those approved by University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC) and the Oregon Health Authority (OHA). Put simply, a backflow preventer ensures water inside fire sprinklers, irrigation systems, and other water-based . The proper backflow device protects the public water supply from possible contamination. prevent backflow. Official Cross-Connection Control Program forms: Listed below are links to the official TCEQ Cross-Connection Control Program forms. Get listed and meet new customers. A sump pump will be required if vaults are unable to be kept free of standing water. Assemblies installed directly on vertical subgrade risers, or off a riser which enters the space at less than one foot and necessitates the addition of a vertical run of pipe to be raised to observe the required 12 minimum elevation, must be approved for vertical installation. Only 5/8x 3/4 Neptune T-10 positive displacement meters with high resolution registers are to be used. 16. For multiple assemblies in a common vault, (Oldcastle Infrastructure or equivalent) centered frame & cover lids may better accommodate installation criteria. The RPDA must be installed at the service connection/point-of-delivery to the premises as outlined herein and as defined by OAR Chapter 333-061-0020. Splices must be made with 3M Scotchlok moisture resistant connectors, part number UR or UY or equivalent. A reduced pressure type assembly must be installed on all water service connections to premises with high-rise buildings (high-rise building: where a building is 75-feet or greater above its lowest finished-floor (slab) elevation to top of structure). Specific criminal history could negatively impact the ability to receive a TCEQ issued occupational license. 772 0 obj <>/Filter/FlateDecode/ID[<71747C618647EA4DBE716392F970CF8B>]/Index[751 47]/Info 750 0 R/Length 99/Prev 434359/Root 752 0 R/Size 798/Type/XRef/W[1 2 1]>>stream On this page: How Cross-Connection and Backflow Can Lead to Contaminated Water Definitions An individual may substitute one year of required experience with: 1 year of College credit (32 Semester Hours), 20 Hours of Approved Training in addition to the required 40-hour Training Course. 3. The simplest method to prevent backflow is to have your backflow 8. 14. Can you always be this careful? A negative or reduced pressure in the supply piping causes backsiphonage much the same way as drinking through a straw. Premises-Isolation Reduced Pressure Backflow Assembly (RPBA) installations requirements. If touch-pad wire must be run underground the wire must be routed through PVC conduit from the meter to the touchpad. is booked, canceled, or Post your job request for free and match with local backflow testers in Houston. Find more information related to vault lid and door applications under the section Additional installation requirements for vaults and enclosures. Licensed BPA testers are also listed in our, TCEQ requires you to have a licensed BPA tester check the BPAwhen it is installed on your irrigation system. Adequate drainage: Backflow assemblies must not be installed in locations subject to flooding. As determined by the Water Bureau, part #8197, 36 X 36 or #8197-Double, 36 X 74 frame and covers may be required. Other elevation criteria as stated herein will apply. regarding the abilities, performance or quality of service of the 1. Ladder orientation must not impede clear access to the assembly and/or vault floor. By replacing pipes before they break, taking steps to ensure that system pressures do not fall during periods of high demand, and asking for the cooperation of customers when there is a risk that system pressures could fall below safe levels, your public water system operator reduces the risk of backflow. endstream endobj 176 0 obj <> endobj 177 0 obj <>/ProcSet[/PDF/Text/ImageB]/XObject<>>>/Rotate 0/Type/Page>> endobj 178 0 obj <>stream Providers are invited to offer quotes for work and can message you directly to understand the job specifics. The following are requirements of the program: The customer agrees to abide by the rules and regulations regarding cross-connection control and backflow prevention outlined in the TCEQ's Customer Service Agreement in order to establish a connection with the City of Longview's potable water supply. For your convenience we provide a list of State Certified Backflow Assembly Testers in our area. 3. Underground piping requires a minimum 3 feet of cover and may also require a permit be taken out from the Fire Marshals office. You can choose anindividual service providers or select all the providers in their area. or the technical guidance. SwiftQuote stores your backflow service history and gives you instant access to your records. A RPBA must be installed on domestic water services to premises where shell buildings are constructed or renovated when occupancy is undetermined at the time of construction and/or renovation. Fax - 941-365-4840 . These devices prevent contaminated water from flowing back into the city's water system, and can also be found in place in many other municipalities in . An approved airgap must be located directly below the relief valve orifice. There are more than 30,000 backflow prevention assemblies in use in the Tucson Water service area. In the Fire sprinkler system piping will be reviewed on a case-by-case basis regarding sleeving. . The bore-sight drain must never be connected to a sewer of any kind, catch basins, sumps, or dry wells. Backflow occurs when water from your property's plumbing flows backward into the City's water system. 2. Emergency: 206-824-0375 Customer Service Inspection Certificate (. Back pressure is the result of a higher pressure in the system The assemblies are to be installed no more than the pipe diameter in inches from the outlet side of the elbows off the Tee. Over the years, we've been providing top-quality plumbing services to customers all across the state of Texas. All services considered non-potable and do not pose a risk to health. All wiring from the touchpad to the bypass meter must be insulated 1 pair solid 22 AWG copper wires secured so as not to interfere with the operation and maintenance of the backflow assembly.